Application Note 8
Analog I/O Board Diagnostics
Applies to: SIGNAL & RTS
NOTE: This note applies to DT-2821 analog I/O boards.
Introduction
If your DT-2821 analog I/O board appears to be malfunctioning, first check your signal
source and all cables and instruments leading to or from the I/O board, including the
SIGNAL I/O cable and panel. Remove any non-essential components and if possible
exchange the others one by one. If you still suspect the board itself, then run the Data
Translation diagnostics on the board. Following are instructions:
1. The DT diagnostics program "DT2821.EXE" is included in the C:\SIGNAL
directory. To execute it, leave SIGNAL, attach to this directory, and type "DT2821"
at the DOS prompt.
2. Select your board model from the menu: DT-21EZ (50 KHz), DT-2821 (50 KHz),
DT-2821F (150 KHz), or DT-2821G (250 KHz). When asked if the board is factory
configured, say YES unless you've rejumpered the board for a different base address
or IRQ.
3. Run the following tests from the main menu and submenus. These tests require no
external connections. Tests not listed below require that external signals be provided
to the board. Within the submenus, it may be necessary to hit <arrow> keys and
<enter> twice. After reporting test results (e.g., "Board Response PASSED") the
program will pause before returning to the submenu - don't hit <enter>, just wait.
Note: the DIO section of the Acceptance Test and the DIO test will fail - this is